Inverters

Vanner | Outback | Genius | Trace 1 | Trace 2 | Exeltech | Sunny Boy

 

Contact Us | Home | About Us

 

Vanner

Visit Vanner

The RE24-4500DGT AC power inverter/charger is the total package in alternative energy power inverter systems for stand-alone, backup or utility power delivering performance, value and reliability. This sine-wave inverter delivers true sine wave form with 324 steps per cycle and features 120/240, 60 Hz split-phase output and uses H-bridge technology to support difficult reactive loads with < 3% THD. Includes a handheld, single line LCD programmable remote control display, compatible with Windowsฎ software for nonvolatile memory. The charger utilizes 4-stage charging and supports GEL, AGM and flooded lead-acid batteries. The internal 30A AC transfer relay accepts grid or generator input and has automatic generator control capabilities. Two-year warranty. UL 1741 listed.

 

RE24-4500DGT shown with RE AC and DC control modules

Inverter Pricing

Model

 DC Voltage

Continuous Pwr. Watts

AC Output Voltage

Charger Amps

Dimensions LxWxH

Weight (lbs)

Part Number

RE24-4500DGT

21-31 V

4500 W

120/240, 60 Hz

100 A

29.5” x 20.5” x 9.25”

95

167024V4500W

RE48-4500

42-62 V

4500 W

120/240, 60 Hz

50 A

29.5” x 20.5” x 9.25”

95

167048V4500W

 

 

 

 

 

 

 

 

 

 

 

Vanner Control Modules

Visit Vanner

The RE Series AC and DC system Control Modules are designed to compliment the RE inverter system providing the total package solution for PV and hybrid power systems, in an attractive wall mounted enclosure. Enclosures are white, powdercoated aluminum equipped with hard wire terminal blocks and convenient conduit knockouts. The DC version incorporates the necessary DC breakers, wiring and switching needs as required by the NEC for connecting

a battery bank to the RE inverter and to solar arrays (or other DC power sources). In addition, the RE-DCM contains a 60 amp PV charge controller for flooded, gel and AGM batteries and can be expanded for up to three-60 amp sources. Also included are three 20 amp DC load breakers and two 20 amp DC source breakers. The AC Control Module includes AC breakers, wiring and switching needs for connecting the Vanner RE series inverter to the utility, inverter, generator and loads. Output wiring connections for 120/240V, 60Hz single phase-3 wire. The AC version features inverter bypass breakers, main AC breaker, eight AC load breakers, AC source 30 amp transfer relays and optional generator start/stop control and low battery warning relays. 48V models – call for availability.

 

Inverter Pricing

Model

 DC Voltage

Rated Power Watts

AC Output Voltage

Dimensions LxWxH

Weight (lbs)

Part Number

RE24-DCM

24

7200

--

29” x 21.5” x 9.25 “

38

167001

RE24-ACM

--

4500

120/240 VAC

29” x 16” x 9.25”

35

167002

RE48-DCM

48

7200

--

29” x 21.5” x 9.25”

38

167003

RE48-ACM

--

4500

120/240 VAC

29” x 16” x 9.25”

35

167004

 

 

 

 

 

 

 

 

 

 

Contact Us | Home | About Us